With Leak Test Rigs of series DHP 145 it is possible to test tightness against over and low-pressure of components of different dimensions and shapes. The leak rate is determined depending on pressure.
The test rig is working at test air temperatures from -40°C up to 120°C. A heat exchanger protects the measurement instrumentation against damages because of too low or high temperatures during low pressure operation.
For external connection the test rig has a test air adapter, a pressure measurement port as well as a temperature sensor which have to be connected with the test sample.
All connecting lines are 2m long so that the sample can be in a climatic chamber during the test. The whole inscpection process is carried out primarily automatic and is controlled by means of the PC-based software DHPWin.
Advantages:
Adaptive Instruments
Unit 4 Franklyn House,
Daux Road, Billingshurst,
West Sussex,
RH14 9SJ, UK
Tel: +44 1403 753333
Fax: +44 1403 753386